Skip to main content

Table 1 Results of 16 different images

From: A user-friendly software to easily count Anopheles egg batches

Image

Ground Truth/

Auto./

Mouse

Output/

Missed

Ref.

MINUTES

Sens.

Clicks

SECONDS

Eggs

01

702 / 29

707

4

711 / 9

1%

02

342 / 20

320

8

366 / 18

7%

03

608 / 40#

399 / 620

11*

620 / 35

2%

04

391 / 21

277 / 400

12*

400 / 35

2%

05

372 / 21

314 / 363

03*

363 / 25

2%

06

219 / 20

212

0

219 / 18

0%

07

460 / 27

478

3

455 / 20

1%

08

086 / 15

102

2

89 / 18

3%

09

114 / 20

118

1

119 / 18

4%

10

280 / 21

300

5

272 / 20

2%

11

352 / 25

342

5

360 / 20

2%

12

480 / 25

701

2

489 / 20

2%

13

022 / 06

23

1

22 / 15

0%

14

297 / 20

267

19

297 / 115

0%

15

331 / 21

358

9

331 / 110

0%

16

311 / 20

302

9

311 / 110

0%

  1. #Automatic sensitivity failed and the software needed to be restarted.
  2. Results after correction of sensitivity.