Skip to main content

Table 1 Sensitivity to hygromycin and lower detection limits of RLAS, EnduRen and CellTiter-Glo with the T.b. gambiense 348BT wild type and three RLuc transfected strains

From: Luminescent multiplex viability assay for Trypanosoma brucei gambiense

Population

IC50hygromycina

RLASb

EnduRenc

CellTiter-Glod

wild type

< 0.12

n.a.

n.a.

218 ± 14

RLuc #2.1

7.5 ± 1.1

207 ± 22

991 ± 131

212 ± 9

RLuc #3.1

2.4 ± 0.7

810 ± 80

4804 ± 511

221 ±16

RLuc #3.2

4.2 ± 0.9

488 ± 50

3225 ± 423

215 ± 22

  1. a reported in μg ml-1 ± SD, from 3 cultures and determined with fluorimetric assay for measurement of reduction of resazurin.
  2. b reported in number of cells ± SD, from 3 cultures and determined with RLAS, a luminescent assay for detection of Renilla luciferase activity in lysed cells.
  3. c reported in number of cells ± SD, from 3 cultures and determined with EnduRen, a luminescent assay for detection of Renilla luciferase activity in living cells.
  4. d reported in number of cells ± SD, from 3 cultures and determined with CellTiter-Glo, a luminescent assay for quantification of ATP.
  5. n.a. = not applicable.