Skip to main content

Table 2 Estimates of parameters affecting Aedes aegypti landing rates in the presence of metofluthrin emanators

From: Reducing biting rates of Aedes aegypti with metofluthrin: investigations in time and space

Parameter

Value

Standard error

95% Confidence interval

Wald χ 2

df

P-value

Intercept

-2.185

0.4663

-3.099–1.271

21.961

1

< 0.0001

Time (-5 min)

3.145

0.4707

2.222–4.067

4.067

1

< 0.0001

Time (10 min)

0.667

0.4658

-0.245–1.580

2.053

1

0.152

Time (30 min)

0.077

0.4686

-0.842–0.995

0.027

1

0.870

Time (60 min)

0.227

0.4673

-0.689–1.143

0.235

1

0.628

Time (120 min)

0.168

0.4702

-0.753–1.090

0.128

1

0.720

Distance (1 m)

-0.489

0.8762

-2.206–1.228

0.311

1

0.577

Room volume

0.015

0.0016

0.012–0.018

85.085

1

< 0.0001

Distance (1 m) * room volume

-0.014

0.0028

-0.020– -0.009

25.930

1

< 0.0001

  1. Parameter estimates are from a generalized estimating equation. All main effects are listed. Only significant two-way interactions are shown